2023-03-29

The role and application of cast voltage transformers

Casting voltage transformers can convert high voltage into a lower standard secondary voltage according to the proportion, so that the equipment voltage meets the rated voltage requirements, and can effectively isolate the high voltage from electrical workers to ensure worker safety. This equipment is developed and produced based on the principle of electromagnetic induction, but its electromagnetic structure has its own characteristics. So, let's learn about the function and application of casting voltage transformers!


2023-03-16

What are the uses of Permalloy cores?

With the continuous advancement of science and technology, all walks of life have also developed greatly. The development prospect of permalloy iron core is also very good, so the demand is increasing, and there are more and more manufacturers on the market. As a manufacturer, it is also very necessary for us to tell you about the uses of permalloy iron core. Interested partners can come and have a look.


2023-03-02

What are the advantages of using a Permalloy core?

The future of the Permalloy core industry is bright, as it offers numerous benefits to businesses, making it highly popular among customers. To help people learn more about it, let's discuss the advantages of Permalloy cores. Hopefully, this will be helpful to many.


2023-02-13

Some basic overviews of powdered metal cores?

The application range of permalloy cores is very wide. Before using it, we need to know some basic overviews of permalloy cores so that we can better apply it. If you are interested in this topic, let's take a look together, hoping to help some relevant people.


2023-01-09

What factors affect the error of a molded current transformer?

The factors affecting the error of shell-type current transformers mainly manifest in two aspects. Knowing the error, how to reduce it? We found that the magnetizing current is the main factor causing the error to increase, so the error can be reduced by reducing the magnetizing current, such as increasing the cross-sectional area of the iron core, shortening the magnetic path length, selecting high-permeability material as the iron core, limiting the secondary load, and appropriately increasing the transformation ratio, etc.


2022-12-29

How can we prevent open circuits in molded-case current transformers? How should the wiring be checked?

How to prevent open circuit of molded-case current transformer? Regarding this issue, the molded-case current transformer company reminds you that when using this type of product, you need to comply with the electrical safety regulations, and the secondary side must be grounded. The main purpose of this is to prevent the high voltage on the primary side from entering the secondary side, thus causing harm to equipment and personnel.


2022-12-20

Under what circumstances should molded-case current transformers be taken out of service? How can their burning be prevented?

In power systems, molded-case current transformers are frequently used; these can be classified as outdoor or indoor types. Their reliability is critical because they measure circuit voltage and performance. Failure can not only lead to inaccurate measurements but also pose a safety hazard.


2022-12-09

What factors affect the error of a molded current transformer?

The internal parameters of the molded-case current transformer are the main factors causing errors. The secondary winding's internal resistance R2 and leakage reactance X2 have a significant impact on the error. If R2 increases, both the ratio error and phase angle error will increase. When X2 increases, the ratio error will increase, but the phase angle error will decrease. To reduce the error value, it is necessary to reduce the values of R2 and X2.


2022-11-29

How to prevent open circuit in molded-case current transformers? How to check the wiring?

How to prevent open circuit of molded-case current transformer? Regarding this issue, the molded-case current transformer manufacturer reminds you that when using this type of product, you need to comply with the electrical safety regulations to know that the secondary side must be grounded. The main purpose of this is to prevent the high voltage on the primary side from entering the secondary side, thus causing harm to equipment and personnel.


2022-11-21

Under what circumstances should molded-case current transformers be taken out of service? How can their burning be prevented?

In power systems, molded-case current transformers are frequently used and are classified into outdoor and indoor types. Their reliability is critical because they measure circuit voltage and performance. Failure can not only lead to inaccurate measurements but also pose safety hazards. Therefore, operation should be stopped immediately if any of the following occur.